ROTO SILENTA 630 RS

YOUR FIRST CHOICE UP TO 12 LITERS

ROTO SILENTA 630 RS

YOUR FIRST CHOICE UP TO 12 LITERS

The ROTO SILENTA 630 RS is highly rated in the rapid and efficient centrifugation of blood bags. It is able to spin up to 12 liter of sample or 12 blood bags per run. Four and six-place rotor options are also available to offer the best possible fit.

In industrial or R&D the ROTO SILENTA accommodated six vessels each up to 2,000 ml.

This unit includes refrigeration with a temperature range from -20°C to +40°C.

Facts & Numbers

 

MAX. CAPACITY: 
6 x 2,000 ml

MAX. RCF:
6,520

MAX. RPM:
6,000 min-1

WEIGHT:
approx. 355 kg

REFRIGERATION: 
Yes

DIMENSIONS (W x D x H): 
813 x 1,015 x 973 mm


Cat. No.: 5005


Fields of Application

Clinical chemistry

Ideal for high-throughput processing of all commercial blood-bag systems, but also for centrifugation of blood collection tubes.

Industry and Research

Specimen like bacteria culture, cell culture, or soil resp. sediment can be spun in large lumen.

Equipped with a high through-put rotor for tubes, flasks and bottles up to 6 x 2,000 ml for cell culture or cultured bacteria.

Facilities

  • Hospitals
  • Blood banks and transfusion medicine laboratories
  • Cell culture laboratories

3 reasons for a ROTO SILENTA

BEST CONDITIONS FOR YOUR LAB           

Silent

The ROTO SILENTA 630 RS lives up to its name it has a maximum noise rating of 62db(A) even when running at full speed and cooling. At lower speeds and temperature settings, the centrifuge is even quieter.

 

Hygienic chamber

The centrifuge chamber is made with medical grade stainless steel and rounded edges to maximize hygiene. Without a rotor windshield, users can clean the chamber thoroughly for a hygienic sample environment.

 

Ergonomics 

With a working height of 91 cm the centrifuge is easy to load and unload. The opening and closing of the lid is aided by gas springs which eliminate most of the effort required to open the centrifuge lid. With the ergonomic handle located in the front of the unit, it is easy to close the lid manually. The motorized lid locking systems will ensure safe and easy locking.

BEST CONDITIONS FOR YOUR BUDGET

Time saving

The Pre-cooling time to 4 °C can be done in under 30 Minutes which reduces the electricity cost and operation time.

Save engergy

The unique Hettich cooling system reduces the need of cooling during standard operation. With the recommended Buffy Coat application settings at 4.000 RCF the centrifuge will need less than 0,60 kw/h power, during operation at 20-22 °C.

 

 

BEST CONDITIONS FOR YOUR SAMPLES

Dual temperature sensors in the chamber

Dual temperature sensors in the chamber provide greater temperature control and more accurate “at sample” temperatures. A total of 4 temperature sensors control the compliance of temperature.

 

Consistent results

The powerful motor is able to consistently produce the same amounts of centrifugal force regardless of sample size or quantity. The difference between spinning 1 or 12 blood bags per conditions is less than 1%. The same separation run can be repeated day after day.

Accessories

We have the right accessories for you!

Get in contact with us, we are happy to assist you in choosing the right rotor and the accessories.

 

01 / 03

Swing-out rotor, 6-places

Angle: 90°

Max. RCF: 6,520

Max. RPM: 4,500 min-1

Max. Capacity: 6 x 2,000 ml

 

Cat. No.: 4176

02 / 03

Swing-out rotor, 4-places

Angle: 90°

Max. RCF: 5,705

Max. RPM: 4,500 min-1

Max. Capacity: 4 x 2,000 ml

 

Cat. No.: 4174

03 / 03

Angle Rotor, 6-places

Angle: 25°

Max. RCF: 5,594

Max. RPM: 6,000 min-1

Bio-Containmend lid: Yes

Max. Capacity: 6 x 250 ml

 

Cat. No.: 4570

Contact



We would be pleased if we can help you with your questions.


Contact